- Below find details on the [terrestrial usecase|http://reap.ecoinformatics.org/Wiki.jsp?page=Land_PlantPath] hardware, some pictures from a dry run setup, screenshots of an example Kepler workflow using the [RBNBToKepler2 actor|http://reap.ecoinformatics.org/Wiki.jsp?page=RBNBSinkActorDesignAndAPI] and the resulting plots. The CRBasic program used to collect these data is also [posted below|TerrestrialUseCaseHardware#Datalogger Program].
+ Below find details on the [terrestrial usecase|http://reap.ecoinformatics.org/Wiki.jsp?page=Land_PlantPath] hardware, some pictures from a dry run setup, screenshots of an example Kepler workflow using the [DataTurbine actor|http://reap.ecoinformatics.org/Wiki.jsp?page=RBNBSinkActorDesignAndAPI] and the resulting plots. The CRBasic program used to collect these data is also [posted below|TerrestrialUseCaseHardware#Datalogger Program].
Line 4 was replaced by line 4
- The datafile that comes out of Loggernet, an ascii comma separated .dat file (LoggerNet "TOA5" format) was parsed and pushed into my RBNB server with a small java program I wrote (DatToRBNB.java). This program can create a new RBNB channelmap using all the data in a TOA5 file or be periodically run on a growing file to append to an existing channelmap. (* currently have a bug w/ append mode periodically dropping old data). DatToRBNB can also be used to pull data from RBNB and print it to stdout (in fact pulling data is also done when pushing using append mode, to gather knowledge about the state of the existing RBNB data before appending).
+ The datafile that comes out of Loggernet, an ascii comma separated .dat file (LoggerNet "TOA5" format) was parsed and pushed into my DataTurbine server with a small java program I wrote (DatToRBNB.java). This program can create a new DataTurbine channelmap using all the data in a TOA5 file or be periodically run on a growing file to append to an existing channelmap. (* currently have a bug w/ append mode periodically dropping old data). DatToRBNB can also be used to pull data from DataTurbine and print it to stdout (in fact pulling data is also done when pushing using append mode, to gather knowledge about the state of the existing DataTurbine data before appending).
Line 6 was replaced by line 6
- ''__Note:__'' Don't try to read too much into these plots--data were collected indoors, from hardware that was occasionally moved about, powered off, etc. DatToRBNB.java and the RBNBToKepler2 actor were both being modified as well.
+ ''__Note:__'' Don't try to read too much into these plots--data were collected indoors, from hardware that was occasionally moved about, powered off, etc. DatToRBNB.java and the DataTurbine actor were both being modified as well.
Line 41 was replaced by line 41
- !Plots
+ !Sensor Hardware with Example Plots
Line 181 was replaced by line 181
- !Computer
+ !Computer (ugly notes-dump that i'll clean up later...:)
Line 194 was replaced by lines 194-195
- __dyndns address must be used at least once monthly for it to not expire__
+ __dyndns address must be used at least once monthly for it to not expire__\\
+ sshd installed using cygwin, following these instructions: http://pigtail.net/LRP/printsrv/cygwin-sshd.html\\
Line 211 was replaced by lines 212-213
- __dyndns address must be used at least once monthly for it to not expire__
+ __dyndns address must be used at least once monthly for it to not expire__\\
+ sshd installed using cygwin, following these instructions: http://pigtail.net/LRP/printsrv/cygwin-sshd.html\\
At line 212 added 8 lines.
+ !UPS:
+ Both systems will be connected to identical UPS, 1 UPS per computer.\\
+ UPS details: APC BE350R "Battery Backup ES Series", 350VA 120V USB 200Watts. 8 outlets, 4 provide battery backup.\\
+ \\
+ APC Powerchute Personal Edition v2.0 installed on each pc. \\
+ Defaults settings kept, except: "Enable battery backup at all times" has been chosen.\\
+ Runtime is by default "Keep my computer on as long as possible". This should give ~7 minutes of pc runtime if pc is the only draw (the other UPS claims 36 minutes when connected to either PC...seems bogus.)
+
Removed lines 215-216
- * sensor experiments
- * take photos
At line 217 added 9 lines.
+
+ !Deployment at Baskett Slough (Dec. 2007):
+ (On slanted ground, it is level despite appearances. Loose cables have since been secured to legs and ground.)
+ [http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1051.jpg|http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1051.jpg]
+ [http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1052.jpg|http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1052.jpg]
+ [http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1053.jpg|http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1053.jpg]
+ [http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1054.jpg|http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1054.jpg]
+ [http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1056.jpg|http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1056.jpg]
+ [http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1057.jpg|http://reap.ecoinformatics.org/attach?page=TerrestrialUseCaseHardware%2FIMG_1057.jpg]

Back to Terrestrial Use Case Hardware, or to the Page History.